Phys Med ; 54: 49-55, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30337010

RESUMO

PURPOSE: The aim of this study was to propose and validate across various clinical scanner systems a straightforward multiparametric quality assurance procedure for proton magnetic resonance spectroscopy (MRS). METHODS: Eighteen clinical 1.5 T and 3 T scanner systems for MRS, from 16 centres and 3 different manufacturers, were enrolled in the study. A standard spherical water phantom was employed by all centres. The acquisition protocol included 3 sets of single (isotropic) voxel (size 20 mm) PRESS acquisitions with unsuppressed water signal and acquisition voxel position at isocenter as well as off-center, repeated 4/5 times within approximately 2 months. Water peak linewidth (LW) and area under the water peak (AP) were estimated. RESULTS: LW values [mean (standard deviation)] were 1.4 (1.0) Hz and 0.8 (0.3) Hz for 3 T and 1.5 T scanners, respectively. The mean (standard deviation) (across all scanners) coefficient of variation of LW and AP for different spatial positions of acquisition voxel were 43% (20%) and 11% (11%), respectively. The mean (standard deviation) phantom T2values were 1145 (50) ms and 1010 (95) ms for 1.5 T and 3 T scanners, respectively. The mean (standard deviation) (across all scanners) coefficients of variation for repeated measurements of LW, AP and T2 were 25% (20%), 10% (14%) and 5% (2%), respectively. CONCLUSIONS: We proposed a straightforward multiparametric and not time consuming quality control protocol for MRS, which can be included in routine and periodic quality assurance procedures. The protocol has been validated and proven to be feasible in a multicentre comparison study of a fairly large number of clinical 1.5 T and 3 T scanner systems.


Assuntos
Espectroscopia de Prótons por Ressonância Magnética/normas , Imagens de Fantasmas , Controle de Qualidade
2.
In Vivo ; 31(3): 415-418, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28438871

RESUMO

AIM: To evaluate the accuracy of multiparametric magnetic resonance imaging apparent diffusion coefficient (mpMRI ADC) in the diagnosis of clinically significant prostate cancer (PCa). PATIENTS AND METHODS: From January 2016 to December 2016, 44 patients who underwent radical prostatectomy for PCa and mpMRI lesions suggestive of cancer were retrospectively evaluated at definitive specimen. The accuracy of suspicious mpMRI prostate imaging reporting and data system (PI-RADS ≥3) vs. ADC values in the diagnosis of Gleason score ≥7 was evaluated. RESULTS: Receiver operating characteristics (ROC) curve analysis gave back an ADC threshold of 0.747×10-3 mm2/s to separate between Gleason Score 6 and ≥7. The diagnostic accuracy of ADC value (cut-off 0.747×10-3 mm2/s) vs. PI-RADS score ≥3 in diagnosing PCa with Gleason score ≥7 was equal to 84% vs. 63.6% with an area under the curve (AUC) ROC of 0.81 vs. 0.71, respectively. CONCLUSION: ADC evaluation could support clinicians in decision making of patients with PI-RADS score <3 at risk for PCa.


Assuntos
Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/patologia , Área Sob a Curva , Imagem de Difusão por Ressonância Magnética/métodos , Humanos , Masculino , Gradação de Tumores/métodos , Próstata/patologia , Prostatectomia/métodos , Neoplasias da Próstata/cirurgia , Curva ROC , Estudos Retrospectivos